Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2025-30025: The communication protocol used between the server process and the service control had a flaw that could lead

29
Routine
HIGH 7.8UPGRADEUPGRADE

CVE-2025-30025 is a high-severity flaw (CVSS 7.8) affecting camera station pro, device manager. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

The communication protocol used between the server process and the service control had a flaw that could lead to a local privilege escalation.

Why this priority

  • High severity

A fixed release or distro patch exists.

Risk facts

CVSS score7.8 (High)
Attack vectorLocal
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.2% (top 92%)
CISA exploited listNo
WeaknessCWE-502
Published2025-07-11
Last modified2026-06-17
Publisher (CNA): Axis Communications AB · Vendor: axis

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

axis camera station pro UPGRADE
Affected: < 6.8.43213
Fixed in: 6.8.43213
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy camera-station-pro || rpm -q camera-station-pro || camera-station-pro --version
2. UPGRADE to 6.8.43213 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade camera-station-pro
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade camera-station-pro
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
axis device manager UPGRADE
Affected: < 5.32.137
Fixed in: 5.32.137
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy device-manager || rpm -q device-manager || device-manager --version
2. UPGRADE to 5.32.137 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade device-manager
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade device-manager
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2025-30025?

camera station pro: upgrade to 6.8.43213; device manager: upgrade to 5.32.137. Exact commands for each OS are on this page.

Is CVE-2025-30025 being exploited?

CVE-2025-30025 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2025-30025 affect?

CVE-2025-30025 affects camera station pro, device manager. Severity is high (CVSS 7.8). The communication protocol used between the server process and the service control had a flaw that could lead to a local privilege escalation.

How urgent is CVE-2025-30025?

Priority 29/100. High severity

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.