Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2025-30420: There is a memory corruption vulnerability due to an out of bounds read in Bitmap::InternalDraw() when using t

30
Routine
HIGH 7.8UPGRADE

CVE-2025-30420 is a high-severity flaw (CVSS 7.8) affecting circuit design suite. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

There is a memory corruption vulnerability due to an out of bounds read in Bitmap::InternalDraw() when using the SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.0 and prior versions.

Why this priority

  • High severity

A fixed release or distro patch exists.

Risk facts

CVSS score7.8 (High)
Attack vectorLocal
Attack complexityLow
Privileges neededNone
User interactionRequired
EPSS exploit chance0.2% (top 90%)
CISA exploited listNo
WeaknessCWE-125
Published2025-05-15
Last modified2026-06-17
Publisher (CNA): National Instruments · Vendor: ni

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

ni circuit design suite UPGRADE
Affected: < 14.3.1
Fixed in: 14.3.1
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy circuit-design-suite || rpm -q circuit-design-suite || circuit-design-suite --version
2. UPGRADE to 14.3.1 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade circuit-design-suite
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade circuit-design-suite
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2025-30420?

circuit design suite: upgrade to 14.3.1. Exact commands for each OS are on this page.

Is CVE-2025-30420 being exploited?

CVE-2025-30420 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2025-30420 affect?

CVE-2025-30420 affects circuit design suite. Severity is high (CVSS 7.8). There is a memory corruption vulnerability due to an out of bounds read in Bitmap::InternalDraw() when using the SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution.

How urgent is CVE-2025-30420?

Priority 30/100. High severity

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.