CVE-2025-46634: Cleartext transmission of sensitive information in the web management portal of the Tenda RX2 Pro 16.03.30.14
CVE-2025-46634 is a high-severity flaw (CVSS 8.2) affecting rx2 pro firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Cleartext transmission of sensitive information in the web management portal of the Tenda RX2 Pro 16.03.30.14 may allow an unauthenticated attacker to authenticate to the web management portal by collecting credentials from observed/collected traffic. It implements encryption, but not until after the user has transmitted the hash of their password in cleartext. The hash can be replayed to authenticate.
Why this priority
- High severity
- Public exploit reference
- Remotely exploitable, no login, no user action
No fix is published yet: follow the downgrade or mitigation steps.
Risk facts
| CVSS score | 8.2 (High) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 0.2% (top 93%) |
| CISA exploited list | No |
| Weakness | CWE-312 |
| Published | 2025-05-01 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-46634?
rx2 pro firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2025-46634 being exploited?
CVE-2025-46634 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-46634 affect?
CVE-2025-46634 affects rx2 pro firmware. Severity is high (CVSS 8.2). Cleartext transmission of sensitive information in the web management portal of the Tenda RX2 Pro 16.03.30.14 may allow an unauthenticated attacker to authenticate to the web management portal by collecting credentials from observed/collect
How urgent is CVE-2025-46634?
Priority 40/100. High severity; Public exploit reference; Remotely exploitable, no login, no user action
Related CVEs
- CVE-2025-46635 HIGH 7.1 MITIGATE An issue was discovered on Tenda RX2 Pro 16.03.30.14 devices
- CVE-2025-46633 HIGH 8.2 MITIGATE Cleartext transmission of sensitive information in the web management portal of the Tenda RX2 Pro 16.03.30.14
- CVE-2025-46632 MEDIUM 6.5 MITIGATE Initialization vector (IV) reuse in the web management portal of the Tenda RX2 Pro 16.03.30.14 may allow an at
- CVE-2025-46631 MEDIUM 6.5 MITIGATE Improper access controls in the web management portal of the Tenda RX2 Pro 16.03.30.14 allows an unauthenticat
- CVE-2025-46630 MEDIUM 6.5 MITIGATE Improper access controls in the web management portal of the Tenda RX2 Pro 16.03.30.14 allows an unauthenticat