Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2025-5162: A vulnerability, which was classified as critical, has been found in H3C SecCenter SMP-E1114P02 up to 20250513

32
Routine
MEDIUM 6.3UPGRADE

CVE-2025-5162 is a medium-severity flaw (CVSS 6.3) affecting seccenter smp-1114p02. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A vulnerability, which was classified as critical, has been found in H3C SecCenter SMP-E1114P02 up to 20250513. Affected by this issue is some unknown functionality of the file /safeEvent/importFile/. The manipulation of the argument logGeneralFile/logGeneralFile_2 leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure bu

Why this priority

  • No elevated risk signals yet

A fixed release or distro patch exists.

Risk facts

CVSS score6.3 (Medium)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.4% (top 61%)
CISA exploited listNo
WeaknessCWE-284, CWE-434
Published2025-05-26
Last modified2026-06-17
Publisher (CNA): VulDB · Vendor: h3c

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

h3c seccenter smp-1114p02 UPGRADE
Affected: <= 20250513
Fixed in: newer than 20250513
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy seccenter-smp-1114p02 || rpm -q seccenter-smp-1114p02 || seccenter-smp-1114p02 --version
2. UPGRADE to newer than 20250513 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade seccenter-smp-1114p02
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade seccenter-smp-1114p02
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2025-5162?

seccenter smp-1114p02: upgrade to newer than 20250513. Exact commands for each OS are on this page.

Is CVE-2025-5162 being exploited?

CVE-2025-5162 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2025-5162 affect?

CVE-2025-5162 affects seccenter smp-1114p02. Severity is medium (CVSS 6.3). A vulnerability, which was classified as critical, has been found in H3C SecCenter SMP-E1114P02 up to 20250513. Affected by this issue is some unknown functionality of the file /safeEvent/importFile/. The manipulation of the argument logGen

How urgent is CVE-2025-5162?

Priority 32/100. No elevated risk signals yet.

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.