CVE-2025-5695: A vulnerability has been found in Teledyne FLIR AX8 up to 1.46.16
CVE-2025-5695 is a medium-severity flaw (CVSS 4.7) affecting flir ax8 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
A vulnerability has been found in Teledyne FLIR AX8 up to 1.46.16. This impacts the function subscribe_to_spot/subscribe_to_delta/subscribe_to_alarm of the file /usr/www/application/models/subscriptions.php of the component Backend. Such manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.49.16 will fix this issue. It is suggest
Why this priority
- EPSS top 6%: very likely to be exploited
- Public exploit reference
A fixed release or distro patch exists.
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-5695?
flir ax8 firmware: upgrade to newer than 1.46.16. Exact commands for each OS are on this page.
Is CVE-2025-5695 being exploited?
CVE-2025-5695 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-5695 affect?
CVE-2025-5695 affects flir ax8 firmware. Severity is medium (CVSS 4.7). A vulnerability has been found in Teledyne FLIR AX8 up to 1.46.16. This impacts the function subscribe_to_spot/subscribe_to_delta/subscribe_to_alarm of the file /usr/www/application/models/subscriptions.php of the component Backend. Such ma
How urgent is CVE-2025-5695?
Priority 45/100. EPSS top 6%: very likely to be exploited; Public exploit reference
Software pages
Related CVEs
- CVE-2025-5127 LOW 3.5 UPGRADE A vulnerability was determined in Teledyne FLIR AX8 up to 1.46.16
- CVE-2025-5126 HIGH 8.8 UPGRADE A vulnerability was found in Teledyne FLIR AX8 up to 1.46.16
- CVE-2024-3013 MEDIUM 6.3 UPGRADE A flaw has been found in Teledyne FLIR AX8 up to 1.46.16
- CVE-2018-25139 HIGH 7.5 MITIGATE FLIR AX8 Thermal Camera 1.32.16 contains an unauthenticated vulnerability that allows remote attackers to acce
- CVE-2018-25138 CRITICAL 9.8 MITIGATE FLIR AX8 Thermal Camera 1.32.16 contains hard-coded SSH and web panel credentials that cannot be changed throu