CVE-2025-58405: The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP
CVE-2025-58405 is a medium-severity flaw (CVSS 6.1) affecting clininet. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses.
Why this priority
- No elevated risk signals yet
A fixed release or distro patch exists.
Risk facts
| CVSS score | 6.1 (Medium) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | Required |
| EPSS exploit chance | 0.2% (top 93%) |
| CISA exploited list | No |
| Weakness | CWE-1021 |
| Published | 2026-03-02 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-58405?
clininet: upgrade to 2025.ms3. Exact commands for each OS are on this page.
Is CVE-2025-58405 being exploited?
CVE-2025-58405 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-58405 affect?
CVE-2025-58405 affects clininet. Severity is medium (CVSS 6.1). The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected. As a result, an attacker can embed the application insid
How urgent is CVE-2025-58405?
Priority 23/100. No elevated risk signals yet.
Related CVEs
- CVE-2025-58406 MEDIUM 4.3 UPGRADE The CGM CLININET application respond without essential security HTTP headers, exposing users to client‑side at
- CVE-2025-58402 HIGH 7.5 UPGRADE The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorizati
- CVE-2025-30042 HIGH 7.8 UPGRADE The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on th