Routine
MEDIUM 6.1DOWNGRADE

CVE-2025-63211 is a medium-severity flaw (CVSS 6.1) affecting vbc server. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Stored cross-site scripting vulnerability in bridgetech VBC Server & Element Manager, firmware versions 6.5.0-9 thru 6.5.0-10, allows attackers to execute arbitrary code via the addName parameter to the /vbc/core/userSetupDoc/userSetupDoc endpoint.

Why this priority

  • Public exploit reference

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score6.1 (Medium)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionRequired
EPSS exploit chance0.3% (top 79%)
CISA exploited listNo
WeaknessCWE-79
Published2025-11-19
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: bridgetech

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

bridgetech vbc server DOWNGRADE
Affected: 6.5.0-9 · 6.5.0-10
Fixed in: no fixed release known
Safe to downgrade to: a release before 6.5.0-9
1. Check installed version
apt-cache policy vbc-server || rpm -q vbc-server || vbc-server --version
2. No fixed release: DOWNGRADE to a release before 6.5.0-9 (Debian / Ubuntu)
apt-cache madison vbc-server sudo apt install vbc-server=<VERSION_BEFORE_6.5.0-9> sudo apt-mark hold vbc-server
2. No fixed release: DOWNGRADE (RHEL / Amazon Linux / Fedora)
dnf --showduplicates list vbc-server sudo dnf downgrade vbc-server-<VERSION_BEFORE_6.5.0-9> sudo dnf versionlock add vbc-server
Downgrade risk
Downgrading can break dependent software and may reopen older bugs. Read the distro advisory first and test on a non-production host.
After downgrade
Restart the service, and keep the package held until a fixed release ships.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2025-63211?

vbc server: downgrade or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2025-63211 being exploited?

CVE-2025-63211 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2025-63211 affect?

CVE-2025-63211 affects vbc server. Severity is medium (CVSS 6.1). Stored cross-site scripting vulnerability in bridgetech VBC Server & Element Manager, firmware versions 6.5.0-9 thru 6.5.0-10, allows attackers to execute arbitrary code via the addName parameter to the /vbc/core/userSetupDoc/userSetupDoc e

How urgent is CVE-2025-63211?

Priority 32/100. Public exploit reference

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.