CVE-2025-64642: NMIS/BioDose V22.02 and previous versions' installation directory paths by default have insecure file permissi
CVE-2025-64642 is a high-severity flaw (CVSS 8.0) affecting biodose\/nmis. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
NMIS/BioDose V22.02 and previous versions' installation directory paths by default have insecure file permissions, which in certain deployment scenarios can enable users on client workstations to modify the program executables and libraries.
Why this priority
- High severity
A fixed release or distro patch exists.
Risk facts
| CVSS score | 8.0 (High) |
| Attack vector | Local |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 0.1% (top 98%) |
| CISA exploited list | No |
| Weakness | CWE-732 |
| Published | 2025-12-02 |
| Last modified | 2026-09-25 |
Last updated 2026-09-25 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-64642?
biodose\/nmis: upgrade to 23.0. Exact commands for each OS are on this page.
Is CVE-2025-64642 being exploited?
CVE-2025-64642 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-64642 affect?
CVE-2025-64642 affects biodose\/nmis. Severity is high (CVSS 8.0). NMIS/BioDose V22.02 and previous versions' installation directory paths by default have insecure file permissions, which in certain deployment scenarios can enable users on client workstations to modify the program executables and libraries
How urgent is CVE-2025-64642?
Priority 28/100. High severity
Related CVEs
- CVE-2025-62575 HIGH 8.3 UPGRADE NMIS/BioDose V22.02 and previous versions rely on a Microsoft SQL Server database
- CVE-2025-64298 HIGH 8.4 UPGRADE NMIS/BioDose V22.02 and previous version installations where the embedded Microsoft SQLServer Express is used
- CVE-2025-61940 HIGH 8.3 UPGRADE NMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the datab
- CVE-2025-64778 HIGH 7.3 UPGRADE NMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded pass