CVE-2025-69700: Tenda FH1203 V2.0.1.6 contains a stack-based buffer overflow vulnerability in the modify_add_client_prio funct
CVE-2025-69700 is a high-severity flaw (CVSS 7.5) affecting fh1203 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Tenda FH1203 V2.0.1.6 contains a stack-based buffer overflow vulnerability in the modify_add_client_prio function, which is reachable via the formSetClientPrio CGI handler.
Why this priority
- High severity
- EPSS top 9%: very likely to be exploited
- Public exploit reference
- Remotely exploitable, no login, no user action
A fixed release or distro patch exists.
Risk facts
| CVSS score | 7.5 (High) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 4.0% (top 9%) |
| CISA exploited list | No |
| Weakness | CWE-121 |
| Published | 2026-02-23 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Exact fixes by distribution
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-69700?
fh1203 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2025-69700 being exploited?
CVE-2025-69700 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-69700 affect?
CVE-2025-69700 affects fh1203 firmware. Severity is high (CVSS 7.5). Tenda FH1203 V2.0.1.6 contains a stack-based buffer overflow vulnerability in the modify_add_client_prio function, which is reachable via the formSetClientPrio CGI handler.
How urgent is CVE-2025-69700?
Priority 59/100. High severity; EPSS top 9%: very likely to be exploited; Public exploit reference; Remotely exploitable, no login, no user action
Related CVEs
- CVE-2025-6113 HIGH 8.8 MITIGATE A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6
- CVE-2024-32311 MEDIUM 6.5 MITIGATE Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanPara
- CVE-2024-32299 HIGH 8.8 MITIGATE Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandl
- CVE-2024-32283 HIGH 7.3 MITIGATE Tenda FH1203 V2.0.1.6 firmware has a command injection vulnerablility in formexeCommand function via the cmdin
- CVE-2024-30607 HIGH 8.0 MITIGATE Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInf