Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2025-8913: Organization Portal System developed by WellChoose has a Local File Inclusion vulnerability, allowing unauthen

52
This month
CRITICAL 9.8REMOTEUPGRADE

CVE-2025-8913 is a critical-severity flaw (CVSS 9.8) affecting organization portal system. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Organization Portal System developed by WellChoose has a Local File Inclusion vulnerability, allowing unauthenticated remote attackers to execute arbitrary code on the server.

Why this priority

  • Critical severity
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score9.8 (Critical)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance0.6% (top 50%)
CISA exploited listNo
WeaknessCWE-98
Published2025-08-13
Last modified2026-06-17
Publisher (CNA): TWCERT/CC · Vendor: wellchoose

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

wellchoose organization portal system UPGRADE
Affected: < IFTOP_P3_2_1_197
Fixed in: IFTOP_P3_2_1_197
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy organization-portal-system || rpm -q organization-portal-system || organization-portal-system --version
2. UPGRADE to IFTOP_P3_2_1_197 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade organization-portal-system
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade organization-portal-system
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2025-8913?

organization portal system: upgrade to IFTOP_P3_2_1_197. Exact commands for each OS are on this page.

Is CVE-2025-8913 being exploited?

CVE-2025-8913 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2025-8913 affect?

CVE-2025-8913 affects organization portal system. Severity is critical (CVSS 9.8). Organization Portal System developed by WellChoose has a Local File Inclusion vulnerability, allowing unauthenticated remote attackers to execute arbitrary code on the server.

How urgent is CVE-2025-8913?

Priority 52/100. Critical severity; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.