Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2025-9297: A vulnerability was detected in Tenda i22 1.0.0.3(4687)

52
This month
HIGH 8.8MITIGATE

CVE-2025-9297 is a high-severity flaw (CVSS 8.8) affecting i22 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

Why this priority

  • High severity
  • Public exploit reference

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score8.8 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance1.1% (top 34%)
CISA exploited listNo
WeaknessCWE-119, CWE-121
Published2025-08-21
Last modified2026-06-17
Publisher (CNA): VulDB · Vendor: tenda

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

tenda i22 firmware MITIGATE
Affected: 1.0.0.3\(4687\)
Fixed in: no fixed release known
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2025-9297?

i22 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2025-9297 being exploited?

CVE-2025-9297 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2025-9297 affect?

CVE-2025-9297 affects i22 firmware. Severity is high (CVSS 8.8). A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can b

How urgent is CVE-2025-9297?

Priority 52/100. High severity; Public exploit reference