CVE-2026-2399: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists tha

24
Routine
MEDIUM 6.1UPGRADE

CVE-2026-2399 is a medium-severity flaw (CVSS 6.1) affecting powerchute serial shutdown. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.

Why this priority

  • No elevated risk signals yet

A fixed release or distro patch exists.

Risk facts

CVSS score6.1 (Medium)
Attack vectorAdjacent network
Attack complexityLow
Privileges neededHigh
User interactionNone
EPSS exploit chance0.2% (top 90%)
CISA exploited listNo
WeaknessCWE-22
Published2026-04-14
Last modified2026-10-26
Publisher (CNA): Schneider Electric SE · Vendor: schneider-electric

Share: LinkedIn · X · Reddit

Last updated 2026-10-26 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

schneider-electric powerchute serial shutdown UPGRADE
Affected: < 1.5
Fixed in: 1.5
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy powerchute-serial-shutdown || rpm -q powerchute-serial-shutdown || powerchute-serial-shutdown --version
2. UPGRADE to 1.5 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade powerchute-serial-shutdown
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade powerchute-serial-shutdown
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2026-2399?

powerchute serial shutdown: upgrade to 1.5. Exact commands for each OS are on this page.

Is CVE-2026-2399 being exploited?

CVE-2026-2399 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2026-2399 affect?

CVE-2026-2399 affects powerchute serial shutdown. Severity is medium (CVSS 6.1). CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.

How urgent is CVE-2026-2399?

Priority 24/100. No elevated risk signals yet.

Software pages

Schneider Electric vulnerabilities

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.