Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2026-24912: The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple end

39
Routine
HIGH 7.3REMOTEMITIGATE

CVE-2026-24912 is a high-severity flaw (CVSS 7.3) affecting epower.ie. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users

Why this priority

  • High severity
  • Remotely exploitable, no login, no user action

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score7.3 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance0.4% (top 65%)
CISA exploited listNo
WeaknessCWE-613
Published2026-03-06
Last modified2026-06-17
Publisher (CNA): ICS-CERT · Vendor: epower

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

epower epower.ie MITIGATE
Affected: all versions
Fixed in: no fixed release known
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy epower.ie || rpm -q epower.ie || epower.ie --version
No fixed or unaffected release known
Apply the vendor mitigation from the advisory, disable the affected feature, or restrict network access.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2026-24912?

epower.ie: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2026-24912 being exploited?

CVE-2026-24912 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2026-24912 affect?

CVE-2026-24912 affects epower.ie. Severity is high (CVSS 7.3). The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables se

How urgent is CVE-2026-24912?

Priority 39/100. High severity; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.