CVE-2026-29124: Multiple SUID root-owned binaries are found in /home/monitor/terminal, /home/monitor/kore-terminal, /home/moni
CVE-2026-29124 is a high-severity flaw (CVSS 7.8) affecting sfx2100 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Multiple SUID root-owned binaries are found in /home/monitor/terminal, /home/monitor/kore-terminal, /home/monitor/IDE-DPack/terminal-dpack, and /home/monitor/IDE-DPack/terminal-dpack2 in International Data Casting (IDC) SFX2100 Satellite Receiver, which may lead to local privlidge escalation from the `monitor` user to root
Why this priority
- High severity
- Public exploit reference
No fix is published yet: follow the downgrade or mitigation steps.
Risk facts
| CVSS score | 7.8 (High) |
| Attack vector | Local |
| Attack complexity | Low |
| Privileges needed | Low |
| User interaction | None |
| EPSS exploit chance | 0.1% (top 98%) |
| CISA exploited list | No |
| Weakness | CWE-269 |
| Published | 2026-03-05 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2026-29124?
sfx2100 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2026-29124 being exploited?
CVE-2026-29124 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2026-29124 affect?
CVE-2026-29124 affects sfx2100 firmware. Severity is high (CVSS 7.8). Multiple SUID root-owned binaries are found in /home/monitor/terminal, /home/monitor/kore-terminal, /home/monitor/IDE-DPack/terminal-dpack, and /home/monitor/IDE-DPack/terminal-dpack2 in International Data Casting (IDC) SFX2100 Satellite Re
How urgent is CVE-2026-29124?
Priority 33/100. High severity; Public exploit reference
Related CVEs
- CVE-2026-29128 CRITICAL 10.0 MITIGATE IDC SFX2100 Satellite Receiver firmware ships with multiple daemon configuration files for routing components
- CVE-2026-29127 HIGH 7.8 MITIGATE The IDC SFX2100 Satellite Receiver sets overly permissive file system permissions on the monitor user's home d
- CVE-2026-29126 HIGH 7.8 MITIGATE Incorrect permission assignment (world-writable file) in /etc/udhcpc/default.script in International Data Cast
- CVE-2026-29125 MEDIUM 4.7 MITIGATE IDC SFX2100 Satalite Recievers set the `/etc/resolv.conf` file to be world-writable by any local user, allowin
- CVE-2026-29123 HIGH 7.8 MITIGATE A SUID root-owned binary in /home/xd/terminal/XDTerminal in International Data Casting (IDC) SFX2100 on Linux