CVE-2026-33945: Incus is a system container and virtual machine manager
CVE-2026-33945 is a critical-severity flaw (CVSS 9.9) affecting incus. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Incus is a system container and virtual machine manager. Incus instances have an option to provide credentials to systemd in the guest. For containers, this is handled through a shared directory. Prior to version 6.23.0, an attacker can set a configuration key named something like `systemd.credential.../../../../../../root/.bashrc` to cause Incus to write outside of the `credentials` directory associated with the container. This makes use of the
Why this priority
- Critical severity
- On your watchlist
A fixed release or distro patch exists.
Risk facts
| CVSS score | 9.9 (Critical) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | Low |
| User interaction | None |
| EPSS exploit chance | 0.5% (top 61%) |
| CISA exploited list | No |
| Weakness | CWE-22 |
| Published | 2026-03-27 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2026-33945?
incus: upgrade to 6.23.0. Exact commands for each OS are on this page.
Is CVE-2026-33945 being exploited?
CVE-2026-33945 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2026-33945 affect?
CVE-2026-33945 affects incus. Severity is critical (CVSS 9.9). Incus is a system container and virtual machine manager. Incus instances have an option to provide credentials to systemd in the guest. For containers, this is handled through a shared directory. Prior to version 6.23.0, an attacker can set
How urgent is CVE-2026-33945?
Priority 49/100. Critical severity; On your watchlist
Related CVEs
- CVE-2026-41648 MEDIUM 5.0 UPGRADE Incus is a system container and virtual machine manager
- CVE-2026-41647 MEDIUM 6.5 UPGRADE Incus is a system container and virtual machine manager
- CVE-2026-41684 MEDIUM 6.5 UPGRADE Incus is a system container and virtual machine manager
- CVE-2026-41685 MEDIUM 4.3 UPGRADE Incus is a system container and virtual machine manager
- CVE-2026-40195 MEDIUM 6.5 UPGRADE Incus is a system container and virtual machine manager