Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2026-35716: A stack-based buffer overflow in the motion_privacy.cgi binary in VIVOTEK FD8136 firmware FD8136-VVTK-0300a al

28
Routine
MEDIUM 6.3MITIGATE

CVE-2026-35716 is a medium-severity flaw (CVSS 6.3) affecting fd8136 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A stack-based buffer overflow in the motion_privacy.cgi binary in VIVOTEK FD8136 firmware FD8136-VVTK-0300a allows authenticated remote attackers to execute arbitrary code as root via an oversized n1 parameter in a POST request to the /cgi-bin/admin/setpm.cgi, /cgi-bin/admin/setmd.cgi, or /cgi-bin/admin/setmd_profile.cgi endpoint (all symlinks to the same binary). The parameter value is copied into a fixed-size 0xa4-byte stack buffer without boun

Why this priority

  • No elevated risk signals yet

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score6.3 (Medium)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.3% (top 75%)
CISA exploited listNo
WeaknessCWE-121
Published2026-06-02
Last modified2026-07-22
Publisher (CNA): MITRE · Vendor: vivotek

Share: LinkedIn · X · Reddit

Last updated 2026-07-22 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

vivotek fd8136 firmware MITIGATE
Affected: 0300a
Fixed in: no fixed release known
Safe to downgrade to: a release before 0300a
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2026-35716?

fd8136 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2026-35716 being exploited?

CVE-2026-35716 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2026-35716 affect?

CVE-2026-35716 affects fd8136 firmware. Severity is medium (CVSS 6.3). A stack-based buffer overflow in the motion_privacy.cgi binary in VIVOTEK FD8136 firmware FD8136-VVTK-0300a allows authenticated remote attackers to execute arbitrary code as root via an oversized n1 parameter in a POST request to the /cgi-

How urgent is CVE-2026-35716?

Priority 28/100. No elevated risk signals yet.

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.