Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2026-50062: A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026

28
Routine
HIGH 7.8DOWNGRADEDOWNGRADE

CVE-2026-50062 is a high-severity flaw (CVSS 7.8) affecting solid edge se2025, solid edge se2026. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Why this priority

  • High severity

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score7.8 (High)
Attack vectorLocal
Attack complexityLow
Privileges neededNone
User interactionRequired
EPSS exploit chance0.2% (top 95%)
CISA exploited listNo
WeaknessCWE-125
Published2026-08-11
Last modified2026-09-10
Publisher (CNA): Siemens AG · Vendor: siemens

Share: LinkedIn · X · Reddit

Last updated 2026-09-10 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

siemens solid edge se2025 DOWNGRADE
Affected: 225.0 · 225.0 update_0001 · 225.0 update_0002 · 225.0 update_0003 · 225.0 update_0004 · 225.0 update_0005 · 225.0 update_0006 · 225.0 update_0007
Fixed in: no fixed release known
Safe to downgrade to: a release before 225.0
1. Check installed version
apt-cache policy solid-edge-se2025 || rpm -q solid-edge-se2025 || solid-edge-se2025 --version
2. No fixed release: DOWNGRADE to a release before 225.0 (Debian / Ubuntu)
apt-cache madison solid-edge-se2025 sudo apt install solid-edge-se2025=<VERSION_BEFORE_225.0> sudo apt-mark hold solid-edge-se2025
2. No fixed release: DOWNGRADE (RHEL / Amazon Linux / Fedora)
dnf --showduplicates list solid-edge-se2025 sudo dnf downgrade solid-edge-se2025-<VERSION_BEFORE_225.0> sudo dnf versionlock add solid-edge-se2025
Downgrade risk
Downgrading can break dependent software and may reopen older bugs. Read the distro advisory first and test on a non-production host.
After downgrade
Restart the service, and keep the package held until a fixed release ships.
siemens solid edge se2026 DOWNGRADE
Affected: 226.0 · 226.0 update_1 · 226.0 update_2 · 226.0 update_3 · 226.0 update_4 · 226.0 update_5 · 226.0 update_6
Fixed in: no fixed release known
Safe to downgrade to: a release before 226.0
1. Check installed version
apt-cache policy solid-edge-se2026 || rpm -q solid-edge-se2026 || solid-edge-se2026 --version
2. No fixed release: DOWNGRADE to a release before 226.0 (Debian / Ubuntu)
apt-cache madison solid-edge-se2026 sudo apt install solid-edge-se2026=<VERSION_BEFORE_226.0> sudo apt-mark hold solid-edge-se2026
2. No fixed release: DOWNGRADE (RHEL / Amazon Linux / Fedora)
dnf --showduplicates list solid-edge-se2026 sudo dnf downgrade solid-edge-se2026-<VERSION_BEFORE_226.0> sudo dnf versionlock add solid-edge-se2026
Downgrade risk
Downgrading can break dependent software and may reopen older bugs. Read the distro advisory first and test on a non-production host.
After downgrade
Restart the service, and keep the package held until a fixed release ships.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2026-50062?

solid edge se2025: downgrade or apply the listed mitigation; solid edge se2026: downgrade or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2026-50062 being exploited?

CVE-2026-50062 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2026-50062 affect?

CVE-2026-50062 affects solid edge se2025, solid edge se2026. Severity is high (CVSS 7.8). A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially c

How urgent is CVE-2026-50062?

Priority 28/100. High severity

Software pages

Siemens vulnerabilities

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.