Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2026-76070: Netis NC63 firmware through V3.0.0.3327 contains a stack-based buffer overflow vulnerability that allows unaut

63
This week
CRITICAL 9.8REMOTE

CVE-2026-76070 is a critical-severity flaw (CVSS 9.8) affecting affected software. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Netis NC63 firmware through V3.0.0.3327 contains a stack-based buffer overflow vulnerability that allows unauthenticated remote attackers to overwrite saved stack state by submitting an oversized Base64-encoded password to the login handler in /bin/netis.cgi. Attackers can exploit the custom Base64 decoder's lack of output length validation against the fixed-size stack buffer to achieve remote code execution with root privileges, as the Boa web s

Why this priority

  • Critical severity
  • CISA SSVC: public proof of concept
  • CISA SSVC: automatable with total technical impact
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score9.8 (Critical)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance1.3% (top 29%)
CISA exploited listNo
WeaknessCWE-121
Published2026-08-24
Last modified2026-10-12
Publisher (CNA): VulnCheck

Share: LinkedIn · X · Reddit

Last updated 2026-10-12 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Timeline

Exact fixes by distribution

Fedora ELN · rust-snpguest · FIXED · 0.11.0-1.eln159 · FEDORA-2026-baa01ba6c8 · source
sudo dnf upgrade --advisory=FEDORA-2026-baa01ba6c8
Fedora 46 · rust-sev · FIXED · 8.0.0-1.fc46 · FEDORA-2026-df06b5fb0c · source
sudo dnf upgrade --advisory=FEDORA-2026-df06b5fb0c

Public exploits and detection

Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.

Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2026-76070?

No fixed release is listed yet. Watch the vendor advisory and apply any mitigation shown on this page.

Is CVE-2026-76070 being exploited?

CVE-2026-76070 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2026-76070 affect?

CVE-2026-76070 affects affected software. Severity is critical (CVSS 9.8). Netis NC63 firmware through V3.0.0.3327 contains a stack-based buffer overflow vulnerability that allows unauthenticated remote attackers to overwrite saved stack state by submitting an oversized Base64-encoded password to the login handler

How urgent is CVE-2026-76070?

Priority 63/100. Critical severity; CISA SSVC: public proof of concept; CISA SSVC: automatable with total technical impact; Remotely exploitable, no login, no user action

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.