<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="../assets/feed.xsl"?><rss version="2.0"><channel><title>PatchTheCVE: bd</title><link>https://patchthecve.com/</link><description>CVEs with upgrade or downgrade fix steps</description><item><title>CVE-2023-29066: The FACSChorus software does not properly assign data access privileges for operating system user accounts</title><link>https://patchthecve.com/cve/CVE-2023-29066.html</link><guid>https://patchthecve.com/cve/CVE-2023-29066.html</guid><pubDate>Wed, 17 Jun 2026 05:49:18 +0000</pubDate><description>LOW 3.2: The FACSChorus software does not properly assign data access privileges for operating system user accounts. A non-administrative OS account can modify information stored in the local application data folders.</description></item><item><title>CVE-2023-29065: The FACSChorus software database can be accessed directly with the privileges of the currently logged-in user</title><link>https://patchthecve.com/cve/CVE-2023-29065.html</link><guid>https://patchthecve.com/cve/CVE-2023-29065.html</guid><pubDate>Wed, 17 Jun 2026 05:49:17 +0000</pubDate><description>MEDIUM 4.1: The FACSChorus software database can be accessed directly with the privileges of the currently logged-in user. A threat actor with physical access could potentially gain credentials, which could be used to alter or destroy data stored in the database.</description></item><item><title>CVE-2023-29064: The FACSChorus software contains sensitive information stored in plaintext</title><link>https://patchthecve.com/cve/CVE-2023-29064.html</link><guid>https://patchthecve.com/cve/CVE-2023-29064.html</guid><pubDate>Wed, 17 Jun 2026 05:49:17 +0000</pubDate><description>MEDIUM 4.1: The FACSChorus software contains sensitive information stored in plaintext. A threat actor could gain hardcoded secrets used by the application, which include tokens and passwords for administrative accounts.</description></item><item><title>CVE-2023-29063: The FACSChorus workstation does not prevent physical access to its PCI express (PCIe) slots, which could allow</title><link>https://patchthecve.com/cve/CVE-2023-29063.html</link><guid>https://patchthecve.com/cve/CVE-2023-29063.html</guid><pubDate>Wed, 17 Jun 2026 05:49:17 +0000</pubDate><description>LOW 2.4: The FACSChorus workstation does not prevent physical access to its PCI express (PCIe) slots, which could allow a threat actor to insert a PCI card designed for memory capture. A threat actor can then isolate sensitive information such as a BitLocker encryption key from a dump of the workstation RAM </description></item><item><title>CVE-2023-29062: The Operating System hosting the FACSChorus application is configured to allow transmission of hashed user cre</title><link>https://patchthecve.com/cve/CVE-2023-29062.html</link><guid>https://patchthecve.com/cve/CVE-2023-29062.html</guid><pubDate>Wed, 17 Jun 2026 05:49:17 +0000</pubDate><description>LOW 3.8: The Operating System hosting the FACSChorus application is configured to allow transmission of hashed user credentials upon user action without adequately validating the identity of the requested resource. This is possible through the use of LLMNR, MBT-NS, or MDNS and will result in NTLMv2 hashes be</description></item><item><title>CVE-2023-29061: There is no BIOS password on the FACSChorus workstation</title><link>https://patchthecve.com/cve/CVE-2023-29061.html</link><guid>https://patchthecve.com/cve/CVE-2023-29061.html</guid><pubDate>Wed, 17 Jun 2026 05:49:17 +0000</pubDate><description>MEDIUM 5.2: There is no BIOS password on the FACSChorus workstation. A threat actor with physical access to the workstation can potentially exploit this vulnerability to access the BIOS configuration and modify the drive boot order and BIOS pre-boot authentication.</description></item><item><title>CVE-2023-29060: The FACSChorus workstation operating system does not restrict what devices can interact with its USB ports</title><link>https://patchthecve.com/cve/CVE-2023-29060.html</link><guid>https://patchthecve.com/cve/CVE-2023-29060.html</guid><pubDate>Wed, 17 Jun 2026 05:49:17 +0000</pubDate><description>MEDIUM 5.4: The FACSChorus workstation operating system does not restrict what devices can interact with its USB ports. If exploited, a threat actor with physical access to the workstation could gain access to system information and potentially exfiltrate data.</description></item><item><title>CVE-2023-30565: An insecure connection between Systems Manager and CQI Reporter application could expose infusion data to an a</title><link>https://patchthecve.com/cve/CVE-2023-30565.html</link><guid>https://patchthecve.com/cve/CVE-2023-30565.html</guid><pubDate>Wed, 17 Jun 2026 05:55:02 +0000</pubDate><description>LOW 3.5: An insecure connection between Systems Manager and CQI Reporter application could expose infusion data to an attacker.</description></item><item><title>CVE-2023-30564: Alaris Systems Manager does not perform input validation during the Device Import Function.</title><link>https://patchthecve.com/cve/CVE-2023-30564.html</link><guid>https://patchthecve.com/cve/CVE-2023-30564.html</guid><pubDate>Wed, 17 Jun 2026 05:55:02 +0000</pubDate><description>MEDIUM 6.9: Alaris Systems Manager does not perform input validation during the Device Import Function.</description></item><item><title>CVE-2023-30563: A malicious file could be uploaded into a System Manager User Import Function resulting in a hijacked session.</title><link>https://patchthecve.com/cve/CVE-2023-30563.html</link><guid>https://patchthecve.com/cve/CVE-2023-30563.html</guid><pubDate>Wed, 17 Jun 2026 05:55:02 +0000</pubDate><description>HIGH 8.2: A malicious file could be uploaded into a System Manager User Import Function resulting in a hijacked session.</description></item><item><title>CVE-2023-30562: A GRE dataset file within Systems Manager can be tampered with and distributed to PCUs</title><link>https://patchthecve.com/cve/CVE-2023-30562.html</link><guid>https://patchthecve.com/cve/CVE-2023-30562.html</guid><pubDate>Wed, 17 Jun 2026 05:55:02 +0000</pubDate><description>MEDIUM 6.7: A GRE dataset file within Systems Manager can be tampered with and distributed to PCUs. 



</description></item><item><title>CVE-2023-30561: The data flowing between the PCU and its modules is insecure</title><link>https://patchthecve.com/cve/CVE-2023-30561.html</link><guid>https://patchthecve.com/cve/CVE-2023-30561.html</guid><pubDate>Wed, 17 Jun 2026 05:55:02 +0000</pubDate><description>MEDIUM 6.1: The data flowing between the PCU and its modules is insecure. A threat actor with physical access could potentially read or modify data by attaching a specially crafted device while an infusion is running.</description></item><item><title>CVE-2023-30560: The configuration from the PCU can be modified without authentication using physical connection to the PCU</title><link>https://patchthecve.com/cve/CVE-2023-30560.html</link><guid>https://patchthecve.com/cve/CVE-2023-30560.html</guid><pubDate>Wed, 17 Jun 2026 05:55:01 +0000</pubDate><description>MEDIUM 6.8: The configuration from the PCU can be modified without authentication using physical connection to the PCU. 







</description></item><item><title>CVE-2023-30559: The firmware update package for the wireless card is not properly signed and can be modified.</title><link>https://patchthecve.com/cve/CVE-2023-30559.html</link><guid>https://patchthecve.com/cve/CVE-2023-30559.html</guid><pubDate>Wed, 17 Jun 2026 05:55:01 +0000</pubDate><description>MEDIUM 5.2: The firmware update package for the wireless card is not properly signed and can be modified.</description></item><item><title>CVE-2022-47376: The Alaris Infusion Central software, versions 1.1 to 1.3.2, may contain a recoverable password after the inst</title><link>https://patchthecve.com/cve/CVE-2022-47376.html</link><guid>https://patchthecve.com/cve/CVE-2022-47376.html</guid><pubDate>Wed, 17 Jun 2026 05:13:26 +0000</pubDate><description>HIGH 7.3: The Alaris Infusion Central software, versions 1.1 to 1.3.2, may contain a recoverable password after the installation. No patient health data is stored in the database, although some site installations may choose to store personal data.</description></item><item><title>CVE-2022-43557: The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 (serial) port interface</title><link>https://patchthecve.com/cve/CVE-2022-43557.html</link><guid>https://patchthecve.com/cve/CVE-2022-43557.html</guid><pubDate>Wed, 17 Jun 2026 05:06:50 +0000</pubDate><description>MEDIUM 5.3: The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 (serial) port interface. If exploited, threat actors with physical access, specialized equipment and knowledge may be able to configure or disable the pump. No electronic protected health information (ePHI), protected hea</description></item><item><title>CVE-2022-40263: BD Totalys MultiProcessor, versions 1.70 and earlier, contain hardcoded credentials</title><link>https://patchthecve.com/cve/CVE-2022-40263.html</link><guid>https://patchthecve.com/cve/CVE-2022-40263.html</guid><pubDate>Wed, 17 Jun 2026 05:01:11 +0000</pubDate><description>MEDIUM 6.6: BD Totalys MultiProcessor, versions 1.70 and earlier, contain hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (ePHI), protected health information (PHI) and personally identifiable inf</description></item></channel></rss>