Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2017-11579: In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for commu

49
This month
HIGH 7.1UPGRADE

CVE-2017-11579 is a high-severity flaw (CVSS 7.1) affecting wi-fi blood pressure monitor firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person.

Why this priority

  • High severity
  • Public exploit reference

A fixed release or distro patch exists.

Risk facts

CVSS score7.1 (High)
Attack vectorAdjacent network
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance1.6% (top 25%)
CISA exploited listNo
WeaknessCWE-254
Published2019-07-02
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: blipcare

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

blipcare wi-fi blood pressure monitor firmware UPGRADE
Affected: <= bp700_10.1
Fixed in: newer than bp700_10.1
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2017-11579?

wi-fi blood pressure monitor firmware: upgrade to newer than bp700_10.1. Exact commands for each OS are on this page.

Is CVE-2017-11579 being exploited?

CVE-2017-11579 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2017-11579 affect?

CVE-2017-11579 affects wi-fi blood pressure monitor firmware. Severity is high (CVSS 7.1). In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to p

How urgent is CVE-2017-11579?

Priority 49/100. High severity; Public exploit reference