CVE-2017-11580: Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Serv

46
This month
MEDIUM 6.5UPGRADE

CVE-2017-11580 is a medium-severity flaw (CVSS 6.5) affecting wi-fi blood pressure monitor firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezo

Why this priority

  • Public exploit reference

A fixed release or distro patch exists.

Risk facts

CVSS score6.5 (Medium)
Attack vectorAdjacent network
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance1.4% (top 27%)
CISA exploited listNo
WeaknessCWE-399
Published2019-07-02
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: blipcare

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

blipcare wi-fi blood pressure monitor firmware UPGRADE
Affected: <= bp700_10.1
Fixed in: newer than bp700_10.1
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2017-11580?

wi-fi blood pressure monitor firmware: upgrade to newer than bp700_10.1. Exact commands for each OS are on this page.

Is CVE-2017-11580 being exploited?

CVE-2017-11580 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2017-11580 affect?

CVE-2017-11580 affects wi-fi blood pressure monitor firmware. Severity is medium (CVSS 6.5). Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP

How urgent is CVE-2017-11580?

Priority 46/100. Public exploit reference

Software pages

Wi-Fi vulnerabilities

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.