CVE-2024-2989: A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6
CVE-2024-2989 is a high-severity flaw (CVSS 8.8) affecting fh1203 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was cont
Why this priority
- High severity
- Public exploit reference
No fix is published yet: follow the downgrade or mitigation steps.
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2024-2989?
fh1203 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2024-2989 being exploited?
CVE-2024-2989 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2024-2989 affect?
CVE-2024-2989 affects fh1203 firmware. Severity is high (CVSS 8.8). A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stac
How urgent is CVE-2024-2989?
Priority 55/100. High severity; Public exploit reference
Related CVEs
- CVE-2025-6113 HIGH 8.8 MITIGATE A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6
- CVE-2025-69700 HIGH 7.5 MITIGATE Tenda FH1203 V2.0.1.6 contains a stack-based buffer overflow vulnerability in the modify_add_client_prio funct
- CVE-2024-32311 MEDIUM 6.5 MITIGATE Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanPara
- CVE-2024-32299 HIGH 8.8 MITIGATE Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandl
- CVE-2024-32283 HIGH 7.3 MITIGATE Tenda FH1203 V2.0.1.6 firmware has a command injection vulnerablility in formexeCommand function via the cmdin