CVE-2025-54304: An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices
CVE-2025-54304 is a critical-severity flaw (CVSS 9.8) affecting ion torrent onetouch 2 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows connections from 127.0.0.1 and 192.168.2.15. If a device is powered on and later connected to a network with DHCP, the device may not be assigned the 192.168.2.15 IP addre
Why this priority
- Critical severity
- Remotely exploitable, no login, no user action
No fix is published yet: follow the downgrade or mitigation steps.
Risk facts
| CVSS score | 9.8 (Critical) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 0.5% (top 57%) |
| CISA exploited list | No |
| Weakness | CWE-200 |
| Published | 2025-12-04 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-54304?
ion torrent onetouch 2 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2025-54304 being exploited?
CVE-2025-54304 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-54304 affect?
CVE-2025-54304 affects ion torrent onetouch 2 firmware. Severity is critical (CVSS 9.8). An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 a
How urgent is CVE-2025-54304?
Priority 50/100. Critical severity; Remotely exploitable, no login, no user action
Related CVEs
- CVE-2025-53963 CRITICAL 9.8 MITIGATE An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices