CVE-2025-66049: Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live
CVE-2025-66049 is a high-severity flaw (CVSS 7.5) affecting ip7137 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has
Why this priority
- High severity
- Remotely exploitable, no login, no user action
No fix is published yet: follow the downgrade or mitigation steps.
Risk facts
| CVSS score | 7.5 (High) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 0.4% (top 65%) |
| CISA exploited list | No |
| Weakness | CWE-306 |
| Published | 2026-01-09 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-66049?
ip7137 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2025-66049 being exploited?
CVE-2025-66049 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-66049 affect?
CVE-2025-66049 affects ip7137 firmware. Severity is high (CVSS 7.5). Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized u
How urgent is CVE-2025-66049?
Priority 40/100. High severity; Remotely exploitable, no login, no user action
Related CVEs
- CVE-2025-66052 HIGH 7.2 MITIGATE Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection
- CVE-2025-66051 MEDIUM 6.5 MITIGATE Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal
- CVE-2025-66050 CRITICAL 9.8 MITIGATE Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logg