CVE-2025-66051: Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal
CVE-2025-66051 is a medium-severity flaw (CVSS 6.5) affecting ip7137 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Why this priority
- No elevated risk signals yet
No fix is published yet: follow the downgrade or mitigation steps.
Risk facts
| CVSS score | 6.5 (Medium) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | Low |
| User interaction | None |
| EPSS exploit chance | 0.8% (top 43%) |
| CISA exploited list | No |
| Weakness | CWE-22 |
| Published | 2026-01-09 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-66051?
ip7137 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2025-66051 being exploited?
CVE-2025-66051 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-66051 affect?
CVE-2025-66051 affects ip7137 firmware. Severity is medium (CVSS 6.5). Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for
How urgent is CVE-2025-66051?
Priority 37/100. No elevated risk signals yet.
Related CVEs
- CVE-2025-66052 HIGH 7.2 MITIGATE Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection
- CVE-2025-66050 CRITICAL 9.8 MITIGATE Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logg
- CVE-2025-66049 HIGH 7.5 MITIGATE Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live