Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2025-66051: Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal

37
Routine
MEDIUM 6.5MITIGATE

CVE-2025-66051 is a medium-severity flaw (CVSS 6.5) affecting ip7137 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

Why this priority

  • No elevated risk signals yet

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score6.5 (Medium)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.8% (top 43%)
CISA exploited listNo
WeaknessCWE-22
Published2026-01-09
Last modified2026-06-17
Publisher (CNA): CERT.PL · Vendor: vivotek

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

vivotek ip7137 firmware MITIGATE
Affected: 0200a
Fixed in: no fixed release known
Safe to downgrade to: a release before 0200a
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2025-66051?

ip7137 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2025-66051 being exploited?

CVE-2025-66051 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2025-66051 affect?

CVE-2025-66051 affects ip7137 firmware. Severity is medium (CVSS 6.5). Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for

How urgent is CVE-2025-66051?

Priority 37/100. No elevated risk signals yet.

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.